High Precision NTC Temperature Sensor For Refrigerator Temperature Test
تفاصيل المنتج:
Place of Origin: | CHINA |
اسم العلامة التجارية: | UCHI |
إصدار الشهادات: | ROHS |
Model Number: | NSB103FX500A |
شروط الدفع والشحن:
Minimum Order Quantity: | 1000PCS |
---|---|
الأسعار: | قابل للتفاوض |
Packaging Details: | BULK |
Delivery Time: | 7 WORKDAY |
Payment Terms: | T/T |
Supply Ability: | 100000000PCS PER MONTH |
معلومات تفصيلية |
|||
إبراز: | ,,ntc probe temperature sensor |
---|
منتوج وصف
High Precision NTC Temperature Sensor For Refrigerator Temperature Test
Quick Detail
1.1 Features
1. High precision high stability
2. Quick temperature response
3. Resistant to heat shock
4. Moisture resistant
5.Excellent quality and high stability by high technical mass production
1.2 Applications
Temperature test in kinds of air-condition,refrigerator,hot boiler,microwave oven.
2.0 Structure And Dimensions
2.1 Standard Configurations And Dimensions
3.0 Part Number Code
×× × ××× × × ××××
① ② ③ ④ ⑤ ⑥
- NTC temperature sensors code
- Housing Type
- Nominal Resistance at 90℃
- Resistance Tolerance(%)
Code | E | F | G | H | J | X |
Tolerance of R90 |
±0.5 | ±1.0 | ±2.0 | ±3.0 | ±5.0 |
Specific tolerance |
- B Value
- Wire Length(mm)
4.0 Performance Parameter
4.1 Resistance(R90)
requirement:R90=1.084KΩ±1%
test method:90℃±0.1℃.(90℃±0.1℃ in the oil.)
4.2Thermal time Constant(τ)
requirement:τMax15s, τMax18s
test method:In the water, When the products be put into the water at 25℃ from the water at 50℃, Thermal time constant is the time that cost by the resistance becoming to be the value at34.2℃.
4.3Dissipation Constant(δ)
requirement:3mw/℃,3mW/℃(min, in air)
test method(The product will be join with the following circuit at 25±0.5℃ in still air.
4.4 Max.rated power
requirement:P≈275mw
calculating method:P≈δ×(80℃-25℃)
80℃ is the maximum temperature that the product is heat by itself.
4.5Insulation resistance
requirement:100MΩ
test condition:At DC 500v.
4.6withstanding voltage
requirement:There shall be no evidence of damage during the test.
test condition:AC 1500V for a One second,Permissible Current 5mA.
4.7Max. Permissible Current
requirement:0.72mA
test condition:The current which can be applied to the sensor for rised upper limit of operating temp. range at 25℃ in still air.
4.8 Temperature -40--105℃
- 0 Reliability Characteristics
Testing item | Requirement | Testing method and condition. |
Temperature Cycling. |
Dielectric withstanding voltage and insulation sistance not change. There shall be no evidence of damage during the test. |
-30℃,10min Room temperature 10min 100℃, 30min [in coolant ] [in water ] |
Charge test |
DC1mA,500hrs. Placed for 500hours Applting DC 1 mA at RT. |
|
Heat resistance test |
Charged 500hours at 100±2℃ in air. |
|
Cold resistance test |
Charged 500hours at -30±2℃ in air. |
|
Bias humidity test | 500hrs.Placed 500hours at 55±2℃ 90%~95%RH. | |
Lead wire crimping strength |
1 min load with 3kg. |
|
Drop test | From height 1m drop on concrete floor 10 times. | |
Vibration test |
Frequency:10~55HZ, Amplitude Modulation:1.52mm one time: 1 min. Direction and time:X,Y and Z direction for 2hrs. |
|
Bump |
adder speed:250m/s2, pulse duration:6ms times:500. |
|
Bending test |
180°for 10 times bending the part between wire and epoxy. |
6.0 Method of the stockpile
6.1 The height of stacks products cannot overbalance four boxes,in the stackpile and the course of transport.
6.2 The packing products of inside must placed desiccant.Allowance used the angone way to transport,but must prevent therain and the snow direct or indirect shower bath and damnification of these products.
6.3 The products are stockpiles candition of the tencperature is about -10℃/+40℃,the opposite humidity not bigger too 80%,acidic and alkalescent of substance,erode gas or radiant point are not should enclose the products.