• Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission
  • Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission
Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission

Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission

تفاصيل المنتج:

مكان المنشأ: Dongguan,China
اسم العلامة التجارية: UCHI
إصدار الشهادات: ROHS,UL,cURus,HF,PB FREE
رقم الموديل: 0603

شروط الدفع والشحن:

الحد الأدنى لكمية: 1 Reel
الأسعار: Negotiable
تفاصيل التغليف: Reel
وقت التسليم: 7 Workday
شروط الدفع: T/T,Western Union,Paypal
القدرة على العرض: 50000000PCS Monthly
افضل سعر اتصل

معلومات تفصيلية

تسليط الضوء:

,

,

mini glass fuses

منتوج وصف

Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission
 
 
0603 Time Delay Surface Mount Fuses For Substations / Outdoor Transmission​ Description
 
06 110 Series are the fuses set the industry standard for performance, reliability and
quality. The solder‐free design provides excellent on‐off and temperature cycling
characteristics during use and also makes our SMD fuses more heat and shock
tolerant than typical subminiature fuses.

 

Electrical Characteristics
Rated Current1.0In2.0In2.5In
1A~8A4 hour minimum1~60 sec5 sec maximum

 

 
 

0603 Time Delay Surface Mount Fuses For Substations / Outdoor Transmission Features

 

High inrush current withstanding capability
Compatible with reflow and wave solder
Ceramic and glass construction
Excellent environmental integrity
One time positive disconnect
Lead Free and Halogen free material

 
 
0603 Time Delay Surface Mount Fuses For Substations / Outdoor Transmission Specifications
 
 

Specification
Part No.

Rated

Voltage

Rated

Current

(A)

Breaking

Capacity (A)

1

Typical Cold.

Resistance

(mOhms) 2

 

Typical Voltage

Drop (mV)

Typical Pre-
Arcing I2t
A2Sec)3

Alpha

Mark

Part No.

DC

 

Rated

Current

(A)

Breaking

Capacity (A)

1

Typical Cold.

Resistance

2

(mOhms)

Typical Voltage

Drop (mV)

Typical Pre-

2

Arcing I t

2 3

(A Sec)

Alpha

Mark

06 100.132V150A257.52950.018B
06 100.1.532V1.550A137.52200.065H
06 100.232V250A721600.115K
06 100.2.532V2.550A521450.14L
06 100.332V350A351300.21O
06 100.3.532V3.550A23.81300.55R
06 100.432V450A211200.52S
06 100.532V550A141101.70T
06 100.632V650A81102.30V
06 100.732V750A5.6903.0X
06 100.832V850A3.5805.2Z

 

 
 

* DC Interrupting Rating (Measured at rated voltage, time constant of less than 50 microseconds, battery source)
* DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25degrees
* Typical Pre-arching I2t are measured at 10In Current

 
 
0603 Time Delay Surface Mount Fuses For Substations / Outdoor Transmission Dimension
 
Drawing not to scale (Unit: mm/inch)
 
Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission 0
 
Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission 1

تريد أن تعرف المزيد من التفاصيل حول هذا المنتج
أنا مهتم بذلك Lead Free Surface Mount Fuses 0603 Time Delay For Substations / Outdoor Transmission هل يمكن أن ترسل لي مزيدًا من التفاصيل مثل النوع والحجم والكمية والمواد وما إلى ذلك.
شكر!